NKT Screened Connectors for Type A & B Interfaces

MV switchgear and transformer connections for 250 A and 400 A

  • For interface type A & B

NKT manufactures a wide range of cables and cable accessories and is the leading supplier of medium voltage screened connectors across much of Australasia

NKT was the first to manufacture silicone rubber cable terminations and now has 50 years’ experience, in applications up to 400 kV.

The range of screened connectors for Type A and Type B interfaces are made from silicone rubber and are quick and easy to assemble. Each connector has an outer conductive layer and an integrated inner conductive layer and field control system. Cable sheath testing can be done without dismantling the connector.

The CSE-A 250 elbow connector (illustrated) is typically used to provide a safe, screened connection up to 250A in 11/22 kV transformers, RMUs and distribution switchgear fitted with Type A bushings with plug-in Ø 7.9 mm according to EN 50180/50181. The CSE-A 250 is widely used in electricity distribution applications in New Zealand.

The CE 24-400 elbow connector and CB 36-400 T-connector provide safe, screened connections up to 400A in MV transformers, RMUs and distribution switchgear fitted with Type B bushings according to EN 50180/50181.

CE 24-400 (22kV)

CB 36-400 (33kV)

Hiko Code

Interface

Rating (A)

System Voltage

Application range

11kV

22kV

33kV

Cross section¹ mm

Insulation diameter mm

Min

Max

Min

Max

NKTCSEA1225001

 

 

250

ü

 

 

10

16

10.0

12.0

NKTCSEA1225002

ü

 

 

25

95

13.0

22.0

NKTCSEA2425001

 

ü

 

10

16

13.0

22.0

NKTCSEA2425002

 

ü

 

25

95

17.0

25.5

NKT2641681

B

400

 

ü

 

25

 95

12.7

25.0

NKT2641683

 

ü

 

95

240

21.2

34.6

NKT2645668

 

 

ü

25

35

17.0

24.3

NKT2645667

 

 

ü

 50

120

21.2

33.6

NKT2645670

 

 

ü

150

300

28.9

40.0

 

Hiko Code

Dimensions

Approx length² mm

Approx depth³ mm

NKTCSEA1225001

210

153

NKTCSEA1225002

NKTCSEA2425001

NKTCSEA2425002

NKT2641681

245

210

NKT2641683

NKT2645668

190

NKT2645667

NKT2645670

 

Notes

  1. Maximum size is for AL or CU RMV conductor
  2. From bushing centre line to end of stress cone
  3. From mounting face to back plug cover
  4. Maximum application range at 11 kV: 70 mm²
  5. Minimum application range at 11 kV: 95 mm²
  6. Minimum application range at 11 kV: 185 mm²

NKT MV Cable Accessories Catalogue

Other literature available on request