NKT TI Indoor Terminations

Connection to air insulated switchgear and transformers up to 36kV

 

The NKT TI indoor termination range is made of silicone rubber for connection to air insulated switchgear and transformers up to 36kV

Features

  • Quick and easy assembly
  • One-piece design with capacitive stress control system
  • Short body
  • Long creepage distance by optimised shed arrangement
  • Use of various cable lug types such as screw type and hexagonal pressing
TI 12 Technical Details for Order for 6/10(12) kV Cables

TI 12 incl. crimp type cable lugs for conductor and screening wires

Cross section

(mm2)

Size of Termination

Ø of Core Insulation (mm)

L1
(mm)

D1
(mm)

D2
(mm)

 

AI

 

Cu

16

1

11.8 – 16.3

195

13

39

26 291 50

26 291 00

25

2

12.7 – 19.2

195

13

39

26 291 51

26 291 01

35

2

12.7 – 19.2

195

13

39

26 291 52

26 291 02

50

2

12.7 – 19.2

190

13

39

26 291 53

26 291 03

70

2

12.7 – 19.2

190

13

39

26 291 54

26 291 04

95

3

17.0 – 28.4

215

13

43

26 291 55

26 291 05

120

3

17.0 – 28.4

220

13

43

26 291 56

26 291 06

150

3

17.0 – 28.4

220

13

43

26 291 57

26 291 07

185

3

17.0 – 28.4

220

17

43

26 291 58

26 291 08

240

3

17.0 – 28.4

220

17

43

26 291 09

 

TI 24 Technical Details for Order for 12/20(24) kV Cables

TI 24 incl. crimp type cable lugs for conductor and screening wires

Cross section

(mm2)

Size of Termination

Ø of Core Insulation (mm)

L1
(mm)

D1
(mm)

D2
(mm)

 

AI

 

Cu

25

3

17.0 – 25.0

250

13

55

26 302 51

26 302 01

35

3

17.0 – 25.0

250

13

55

26 302 52

26 302 02

50

3

17.0 – 25.0

250

13

55

26 302 53

26 302 03

70

3

17.0 – 25.0

250

13

55

26 302 54

26 302 04

95

5

21.2 – 34.6

250

13

60

26 563 55

26 302 05

120

5

21.2 – 34.6

255

13

60

26 563 56

26 302 06

150

5

21.2 – 34.6

260

13

60

26 563 57

26 563 07

185

5

21.2 – 34.6

260

17

60

26 563 58

26 563 08

240

5

21.2 – 34.6

260

17

60

26 563 59

26 563 09

 

TI 36 Technical Details for Order for 18/30(36) kV Cables

TI 36 incl. crimp type cable lugs for conductor and screening wires

Cross section

(mm2)

Size of Termination

Ø of Core Insulation (mm)

L1
(mm)

D1
(mm)

D2
(mm)

 

AI

 

Cu

95

5

21.2 – 34.6

310

13

90

26 392 55

26 392 05

120

5

21.2 – 34.6

315

13

90

26 392 56

26 392 06

150

27

28.9 – 43.0

370

13

90

26 392 67

26 392 17

185

27

28.9 – 43.0

370

17

90

26 392 68

26 392 18

240

27

28.9 – 43.0

370

17

90

26 392 69

26 392 19

 

NKT MV Cable Accessories Catalogue

Other literature available on request

Reports, drawings, technical data sheets, installation instructions, O&M guidelines