NKT CPI Branch Joint (JPI3-4W)

The JPI3‑4W is a new branch joint designed to enable ‘spider‑web’ configurations instead of the traditional daisy‑chain layout. This allows cables to be collected at the bottom of the terrain – instead of returning up to the next turbine – which means the routing is more direct and you need less cable.

 

The NKT JPI3‑4W branch joint is designed specifically for use with the CPI 3 inner cone connector from NKT.

Features

  • Connect up to three strings per phase of turbines
  • Combine or branch circuits efficiently
  • Lay cables more directly across complex terrain
  • Reduce total trenching and cable length
  • Improve flexibility when designing the network
Basic information

Type designation                                              Branch joint / transition system

Variant                                                                                      Interface 3 connection

Applicable standards                                                       HD 629.1 + IEC 60840

Contact system

Bushing type                                                                     Interface type 3

 

Electrical routine test (internal)

AC withstand voltage (1 min)                                                                     86 kV

Partial discharge test < 10 pC at                                                               42 kV

X-ray                                                                                                                         100 %

Cable connection

Type                                                                                   CPI 3 and CPI 3XL

Screen type                                                                            CWS and CTS

Mechanical protection

Material hardness                                                                               > 80 Shore D

Termite protection – Appl. Std.                                                         AS 3660.1

Electrical test level of the type test

(IEC 60840:2011+HD 629.1)

AC withstand voltage (5 min)                                                  93.5 kV

LI withstand voltage                                                                      250 kV

Heating cycles (AC voltage)                                                         52 kV

Partial discharge test < 10 pC at                                               42 kV

Electrical levels (IEC 60840)

Rated voltage (Um)                                                                                           52 kV

Highest voltage phase to phase (U)                                               45…47 kV

Rated design voltage to ground (U0)                                                      26 kV

Current

Max. current rating                                                                                    1250A

Max. thermal short circuit current (5s)                                            40 kA

Max. dynamic short circuit current                                                        n.a.

Stress control

Field control method                     geometrical

Type                                                   pre-moulded

Material                                              epoxy resin

Production method                 vacuum casting

Packing

Type                                                                                                       wooden box

Scope of delivery                                                  1 piece per wooden box

Gross weight 1pc                                                                                          30 kg

Dimensions 1pc                                                            450 x 370 x 200 mm

NKT MV Cable Accessories Catalogue

Other literature available on request