Insulect Disconnectors and Earthing Switches

Disconnectors and Earthing Switches 12kV to 145kV

 

 

The Disconnector range from our brand partner, Insulect, is designed to accommodate each customer’s needs and the layout of each substation. The disconnector range is based on a rotary double break design, with or without integrated Earthing Switch. Disconnectors are built for either manual operation or with a motor operated mechanism, for local or remote operation. Disconnectors are designed for horizontal or vertical applications, and may be mounted on steel structures or pole mounted.

The disconnectors can be customised to suit specific substation layouts, configurations and structure types. A variety of insulator types can be accommodated for each voltage level, including electrical and mechanical ratings and pollution levels.

All contact surfaces are silver plated copper. Copper components other than the contact surfaces are tin plated as standard. The moving blades are supplied with a spring loaded flicker to quickly extinguish residual current arcing when the switch is opened live.

Independent single or double earthing switches can be supplied with the disconnectors.

Rating, according to IEC 60694 

 

Rated Voltage

(kV rms)

Rated Lightning Impulse Withstand Voltage kV (peak)

Rated 1 Min Power Frequency Withstand Voltage kV (rms)

To Earth and between Poles (Common Value)

Across the insulating distance

To Earth and between Poles (Common Value)

Across the insulating distance

12

75

85

28

32

24

125

145

50

60

36

170

195

70

80

72.5

325

375

140

160

145

650

750

275

315

 

Normal/Short Circuit Current Rating, according to AS62271-102 / IEC62271-102 

Rated Voltage

(kV rms)

Current Rating Continuous

(A)

Short Circuit Withstand Current and Duration (A/sec)

LIWV (kVp) BIL

12 / 24

600 – 2500

Up to 31.5 kA/3sec

125 kV

36

600 – 3500

Up to 31.5 kA/3sec

170 kV

72.5

600 – 2500

Up to 40.0 kA/3sec

325 kV

145

600 – 2500

Up to 50.0 kA/3sec

650 kV

 

Associated Earth Switch Ratings 

Voltage

Short Circuit Withstand Current

LIWV

12 / 24

Up to 31.5 kA/3sec

125 kV

36

Up to 31.5 kA/3sec

170 kV

72.5

Up to 31.5 kA/3sec

325 kV

145

Up to 50.0 kA/1sec

650 kV

 

Mechanical Endurance Class

AKPS Disconnectors are built and tested to M1 class mechanical endurance suitable for operating cycles of 2000 operations, as per AS 62271.102-2005 & AS 2650-2005.

Other literature available on request

Reports, drawings, technical data sheets, installation instructions, O&M guidelines